At steel lintels above windows in Columbia, how far should the edge of the through-wall flashing project beyond the edge of the lintel? I would think that the flashing does not need to extend beyond the outside edge of the lintel as any water reaching this location will just fall down to the windowsill below.

The Home Depot
(803)736-1666
7701 Two Notch Rd
Columbia, SC
Hours
Mon-Sat: 6:00am-10:00pm
Sun: 8:00am-8:00pm

The Home Depot
(803)419-9336
285 Forum Drive
Columbia, SC
Hours
Mon-Sat: 6:00am-10:00pm
Sun: 8:00am-8:00pm

ABC Supply Co., Inc./Columbia
803-771-4402
855 Brookwood Dr Columbia, SC, 29201
Columbia, SC
 
Ace Hardware of Cayce LLC
(803) 391-4223
815 State St, Parkland Plaza / Bi-Lo Shopping Center
Cayce, SC
 
MANN TOOL & SUPPLY
803-252-7777
802 CHRIS DR. COLUMBIA, SC, 29169
Columbia, SC
 
The Home Depot
(803)781-0877
5200 Fernandina Rd
Columbia, SC
Hours
Mon-Sat: 6:00am-10:00pm
Sun: 8:00am-8:00pm

The Home Depot
(803)359-1194
5600 Sun Set Blvd
Lexington, SC
Hours
Mon-Sat: 6:00am-10:00pm
Sun: 1:30pm-8:00pm

Fastenal- Columbia
803-779-4322
1601 Shop Road Suite 1 Columbia, SC, 29201
Columbia, SC
 
West Columbia - D
(803) 794-9150
1500 Charleston Hwy
West Columbia, SC
Store Hours
Miscellaneous
Store Type
Miscellaneous
Hours
Mon:8-22
Tue:8-22
Wed:8-22
Thu:8-22
Fri:8-22
Sat:8-22
Sun:8-21
Store Features
Mon:8-22
Tue:8-22
Wed:8-22
Thu:8-22
Fri:8-22
Sat:8-22
Sun:8-21

Lowe's
(803) 647-7356
7420 Garners Ferry Road
Columbia, SC
Hours
M-SA 6 am - 10 pm
SU 8 am - 8 pm

Steel Lintels

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2000

At steel lintels above windows, how far should the edge of the through-wall flashing project beyond the edge of the lintel? I would think that the flashing does not need to extend beyond the outside edge of the lintel as any water reaching this location will just fall down to the windowsill below.

I generally recommend projecting the flashing out beyond the face of the brick, which may be 1 inch or so beyond the edge of the lintel. At the jambs, the lintel flashing will continue beyond the end of the lintel, which typically extends 4 to 8 inches into the wall beyond the window jambs. At this point, sealant must be placed between the underside of the flashing and the top of the brick below in order to prevent leakage. I typically use a metal edge strip or rigid metal flashing above lintels to create a straight, clean flashing edge along the entire length of the lintel. If the flashing does not project to or beyond the face of the masonry, it will not be possible to create a seal between the bottom of the flashing and the top of the masonry below. If the flashing at the window jambs is concealed, water reaching this location will flow around the toe of the lintel and down to the masonry at the jambs, contributing to leakage and deterioration problems.